Mecer 10000VA (10kva) (8000W) Smart Tower UPS single phase
- MECER 10000VA 8000W Smart UPS
- With AVR, Monitoring Software plus Cable and Built-in Surge Protection.
- Has Serial and USB ports with a parallel kit.
- Uses 20 x12V 9Ah batteries
Mecer Winner Pro 10000VA On-Line Tower UPS – ME-10000-WPTU
ME-10000-WPTU
New product
Features
• True double-conversion online UPS
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.99
• Output power factor 0.8
• Converter mode available
• ECO mode operation for energy saving (only available for 1-3KVA)
• Generator compatible
• Adjustable battery numbers are only available for 6K and up models
• Smart SNMP works well with either USB or RS-232 together
• Emergency power off function only available for 6K and up models
MORE INFO
MODEL: ME-10000-WPTU
PHASE: Single phase with ground
CAPACITY: 10000VA / 8000W
(with AVR,Monitoring Software + Cable & Built-in Surge Protection) – Black
INPUT
Voltage Range
Low Line Transfer: 176 VAC ± 3% @ 100% load, 110 VAC ± 3% @ 50% load
Low Line Comeback: 186 VAC ± 3% @ 100% load, 120 VAC ± 3% @ 50% load
High Line Transfer: 300 VAC ± 3%
High Line Comeback: 290 VAC ± 3%
Frequency Range: 46~54 Hz or 56~64 Hz
Power Factor: ≧ 0.99 @ 100%load
OUTPUT
Output Voltage: 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode): ± 1%
Frequency Range (Synchronized Range): 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode): 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio: 3:1
Transfer Time
AC Mode to Batt. Mode: Zero
Inverter to Bypass: Zero
Waveform (Batt. Mode): Pure Sinewave
Harmonic Distortion: ≦ 3 % THD (Linear Load), ≦ 5 % THD (Non-linear Load)
EFFICIENCY
AC Mode: 93%
Battery Mode: 91%
BATTERY
Battery Type: 12 V / 9 Ah
Numbers: 16
Typical Recharge Time: 9 hours recover to 90% capacity
Charging Current (max.): 1.0 A / 2.0 A (adjustable)
Charging Voltage: 218.4 VDC ±1%
INDICATORS
LCD Panel: UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode: Sounding every 4 seconds
Low Battery: Sounding every second
Overload: Sounding twice every second
Fault: Continuously sounding
PHYSICAL
Dimension, D x W x H (mm): 442 x 190 x 688
Net Weight (kgs): 66
ENVIRONMENT
Humidity: 0-95 % RH @ 0- 40°C (non-condensing)
Noise Level: Less than 58dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB: Supports Windows 2000/2003/XP/Vista/ 2008, Windows 7/8, Linux, Unix, and MAC
Optional SNMP: Power management from SNMP manager and web browser
NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.